Journal of Information Technology in Construction
ITcon Vol. 27, pg. 461-485, http://www.itcon.org/2022/22
Rateworkspace: BIM integrated post-occupancy evaluation system for office buildings
DOI: | 10.36680/j.itcon.2022.022 | |
submitted: | November 2021 | |
revised: | March 2022 | |
published: | April 2022 | |
editor(s): | Amor R | |
authors: | Deniz Artan, Associate Professor,
Department of Civil Engineering, Istanbul Technical University, Istanbul, Turkey; artande@itu.edu.tr Esin Ergen, Professor, Department of Civil Engineering, Istanbul Technical University, Istanbul, Turkey; esin.ergen@itu.edu.tr Behlul Kula, PhD Student, Department of Civil Engineering, Istanbul Technical University, Istanbul, Turkey; kulab@itu.edu.tr Gursans Guven , Assistant Professor, Department of Civil Engineering, Ozyegin University, Istanbul, Turkey; gursans.guven@ozyegin.edu.tr | |
summary: | The feedback obtained from occupants regarding their comfort needs and performance of buildings is critical for assessing occupant satisfaction, identifying the operation and maintenance (O&M) issues in time and for improving resource efficiency in buildings. Current facility management (FM) systems and occupant feedback collection practices, however, have limitations in supporting effective decision-making in FM, as they lack the necessary contextual data related to the occupant feedback (e.g., building geometry, systems, elements). Building Information Modeling (BIM)-enabled FM systems are used for combining different types of FM information with building models; however, occupant feedback is still not effectively utilized in FM since it is not integrated with BIM. In this study, a BIM integrated post-occupancy evaluation system prototype is developed for: (1) collecting occupant feedback along with the contextual information related to the feedback items in a structured way, and (2) presenting this information as integrated with BIM to the facility managers. This enables conducting spatio-temporal queries and supports effective decision-making by visualizing the collected feedback. The prototype was designed by using qualitative shadowing with FM teams to identify information needs and use case analysis to determine how contextual data integrated with BIM could be collected from office occupants who are non-technical persons with limited information on building models. This paper identifies the FM query categories that are required to process the occupant feedback and describes the RateWorkSpace prototype developed for office buildings. The deployment of the prototype in a real-world office demonstrates that the proposed system is applicable, practical, usable, and that real-time building performance data can be both collected and analysed with the developed system. This has the potential to increase the effectiveness of the FM and O&M processes, and help to create office spaces with optimized energy use and occupant comfort that also supports occupant well-being and productivity. | |
keywords: | facility management, occupant feedback, post-occupancy evaluation (POE), building information modeling (BIM), office buildings, use case analysis | |
full text: | (PDF file, 1.475 MB) | |
citation: | Artan D, Ergen E, Kula B, Guven G (2022). Rateworkspace: BIM integrated post-occupancy evaluation system for office buildings, ITcon Vol. 27, pg. 461-485, https://doi.org/10.36680/j.itcon.2022.022 | |
statistics: |